dc/dc converters thb 6 series, 6 watt features i/o isolation 3000 vacrms rated for 300 vrms working voltage medical safety to ul 60601-1 and iec/en 60601-1 3rd edition, 2 x moop industrial safety to iec/en/ul 60950-1 ultra compact dip-24 package wide 2:1 input voltage ranges operating temperature range C40c to +71c low leakage current short circuit protection input flter to meet en 55022, class a 3-year product warranty the thb 6 series is a new range of high performance, regulated dc/dc converters in a dip-24 plastic package. a reinforced i/o-isolation system and a wide 2:1 input voltage range make this product the best choice for many demanding applications like transportation systems, industrial controls, medical equipment, instrumentation, everywhere where high basic-, supplementary- or reinforced insulation is required to meet requested safety standards. a high effciency allows safe operation in a temperature range of C40c to +71c. other features of this product are over voltage protection and internal emi-input flter to meet en 55022 class a without additional components. full smd-design with exclusive use of ceramic capacitors ensures a very high reliability and a long product lifetime. order code input voltage range output voltage output current max. effciency typ. thb 6-1211 5 vdc 1000 ma 75 % thb 6-1212 9 - 18 vdc 12 vdc 500 ma 78 % thb 6-1222 (12 vdc nominal) 12 vdc 250 ma 78 % thb 6-1223 15 vdc 200 ma 78 % thb 6-2411 5 vdc 1000 ma 77 % thb 6-2412 18 - 36 vdc 12 vdc 500 ma 80 % thb 6-2422 (24 vdc nominal) 12 vdc 250 ma 80 % thb 6-2423 15 vdc 200 ma 80 % thb 6-4811 5 vdc 1000 ma 77 % thb 6-4812 36 - 75 vdc 12 vdc 500 ma 80 % thb 6-4822 (48 vdc nominal) 12 vdc 250 ma 80 % thb 6-4823 15 vdc 200 ma 80 % models page 1 of 3 c b scheme u l 60950 -1 ul 60601-1 u l 60950 -1 iec 60950 -1 iec 60601-1 http://www.tracopower.com
dc/dc converters thb 6 series 6 watt all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. page 2 of 3 input specifications input current at no load / full load 12 vin; 5 vdc model: 30 ma typ. / 570 ma typ. 12 vin; other models: 30 ma typ. / 640 ma typ. 24 vin; 5 vdc model: 20 ma typ. / 280 ma typ. 24 vin; other models: 20 ma typ. / 315 ma typ. 48 vin; 5 vdc model: 10 ma typ. / 140 ma typ. 48 vin; other models: 10 ma typ. / 155 ma typ. start-up voltage / 12 vin models: 9 vdc / 8.5 vdc typ. under voltage shut down 24 vin models: 18 vdc / 16 vdc typ. 48 vin models: 36 vdc / 34 vdc typ. recommended external input fuse (slow blow) 12 vin models: 1.2 a 24 vin models: 0.6 a 48 vin models: 0.3 a surge voltage (1 sec. max.) 12 vin models: 25 vdc max. 24 vin models: 50 vdc max. 48 vin models: 100 vdc max. input filter en 55022 class a output specifications voltage set accuracy 1.0 % regulation C input variation vin min. to vin max. 1.0 % max. C load variation 25 C 100 %: single output models: 1.0 % max. dual output models: 2.0 % max. balanced load minimum load 20 % of rated max. output current. (operation at lower load is safe but major deviations to specified data may occur) ripple and noise (20 mhz bandwidth) 5 vdc models: 100 mvp-p max. other models: 150 mvp-p max. transient response (25% load step change) 500 s max. current limitation >120 % iout max. short circuit protection indefinite (automatic recovery) capacitive load 5 vdc output models: 1000 f max. 12 vdc output models: 470 f max. dual output models: 220 f max. (each output) isolation / safety standards isolation test voltage (flash tested 1 sec.) 6000 vpk i/o isolation voltage C according iec/en 60601-1 3000 vacrms, rated for 300 vrms working (50hz, 60sec.) voltage, 2 x moop C according iec/en 60950-1 4800 vacrms, rated for 300 vrms working voltage leakage current (at 240vac, 60hz) 2 a i/o isolation capacity (at 100khz, 1v) 7 pf typ. i/o isolation resistance (at 500vdc) >1000 mohm safety standards iec 60950-1:2005 (2nd ed.) +a1:2009 and/or en 60950-1:2006 +a1:2010 +a11:2009 +12 :2011, u l 60950 -1 csa c22.2 no. 60950-1-03 iec/en 60601-1 3rd edition, 2 x moop, ul 60601-1, csa c22.2 no. 601.1 safety approvals C cb test certificate according iec 60950-1 www.tracopower.com/products/thb6-cb60950.pdf C cb test certificate according iec 60601-1(3rd edition) www.tracopower.com/products/thb6-cb60601.pdf C csa certificate according ul 60950-1/60601-1 www.tracopower.com/products/thb6-csa.pdf C ul certificate to ul 60950-1 file e188913 cond.: reinforced insulation rated for 55c max. with power de-rating 3%/k above 45c ambient. file copy : e188913qqgq2.pdf http://www.tracopower.com
page 3 of 3 dc/dc converters thb 6 series 6 watt outline dimensions rev. .may 06, 2013 pin single dual 1 +vin (vcc) +vin (vcc) 11 no pin common 12 Cvout no pin 13 +vout Cvout 15 no pin +vout 23 Cvin (gnd) Cvin (gnd) 24 Cvin (gnd) Cvin (gnd) pin-out dimensions in [mm], () = inch pin diameter ? 0.6 0.05 (0.024 0.002) tolerances 0.25 (0.01) pin pich tolerances 0.13 (0.005) general specifications temperature ranges C operating C40c to +71c C case +95c max. C storage C40c to +125c derating 3.0 %/k above 60c humidity (non condensing) 95 % rel h max. temperature coefficient 0.02 %/k typ. reliability, calculated mtbf ( m i l- h d b k-217 f at 25c, ground benign ) >700000 h switching frequency 150 khz typ. (puls width modulation) altitude during operation up to 5000 m (16400 ft) approved environmental compliance C reach www.tracopower.com/products/thb6-reach.pdf C rohs rohs directive 2011/65/eu physical specifications casing material non conductive plastic (ul 94v-0-rated) potting material silicon tse 3331 (ul 94v-0-rated) weight 18 g (0.63 oz) soldering temperature max. 265c / 10 sec. 31.8 2x2.54 20.32 2.54 2.0 0.5 12.0 3.8 (1.25) (0.8) (0.1) (2x0.1) (0.08) (0.47) (0.15) (0.02) 2.54 20.3 15.2 (0.8) (0.6) (0.1) bottom view 11 1 12 13 15 23 24 - the component is not be used in an oxygen rich environment. - the component is not to be used in conjunction with fammable anaesthetics and agents. - the component has to be disposed appropriately. please refer to local regulations (waste electrical and electronic equipment). - a modifcation of the component is not allowed. application note : www.tracopower.com/products/thb6 -appl ication.pdf sp ec i?cati ons can be changed wi thout noti ce! make sure you are using the latest documentation, downloadable at www.tracopower. com www .tracopower. com
|